BKMGX - 106 5259 EKTACHROME R-3000 BLEACH-FIX,PART

  • MSDS: BKMGX
  • Manufacturer: EASTMAN KODAK CO
  • Product Name: 106 5259 EKTACHROME R-3000 BLEACH-FIX,PART
  • National Stock Number: 6750-01-112-2604
Product Identification

Product ID:106 5259 EKTACHROME R-3000 BLEACH-FIX,PART
MSDS Date:02/01/1991
FSC:6750
NIIN:01-112-2604
Kit Part:Y
MSDS Number: BKMGX

Responsible Party
EASTMAN KODAK CO.
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151 (72-1)

Info Phone: 716-722-5151

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 50 - 55%


AMMONIUM THIOSULFATE

CAS: 7783-18-8

RTECS: XN6465000

Fraction By Weight: 40 - 45%


SODIUM METABISULFITE

CAS: 7681-57-4

RTECS: UX8225000

Fraction By Weight: 1 - 5%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3; 9192


AMMONIUM BISULFITE (SARA III)

CAS: 10192-30-0

RTECS: WT3595000

Fraction By Weight: 1 - 5%

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


AMMONIUM ACETATE (SARA III)

CAS: 631-61-8

RTECS: AF3675000

Fraction By Weight: 1 - 5%

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE-INHALATION/SKIN:LOW HAZARD FOR
RECOMMENDED HANDLING.EYES:MAY CAUSE TRANSIENT
IRRITATION.INGESTION:EXPECTED TO BE A LOW INGESTION
HAZARD.CHRONIC-NOT GIVEN.
Explanation of Carcinogenicity:THIS PRODUCT CONTAINS NO INGREDIENT
LISTED AS CARCINOGEN BY IARC,NTP, OR OSHA.
Effects of Overexposure:SEE HEALTH HAZARDS SECTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:GET MEDICAL ATTENTION IF SYMPTOMS OCCUR.EYES:IMMEDIATELY
FLUSH WITH WATER FOR AT LEAST 15 MINUTES.SKIN:FLUSH WITH PLENTY OF
SOAP & WATER.INHALATION:REMOVE TO FRESH AIR.INGESTION:IF
CONSCIOUS,DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONE
Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN AND EYES.
Unusual Fire/Explosion Hazard:FIRE/EXCESSIVE HEAT MAY CAUSE PRODUCTION
OF HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:FLUSH SPILLS TO SEWER WITH LARGE AMOUNT OF
WATER.
Neutralizing Agent:NOT GIVEN

Handling

Handling and Storage Precautions:STORAGE-KEEP CONTAINER TIGHTLY CLOSED
& AWAY FROM ACIDS.
Other Precautions:AVOID BREATHING VAPORS. AVOID CONTACT WITH
EYES,SKIN,OR CLOTHING. WASH THOROUGHLY AFTER HANDLING.USE
VENTILATION THAT IS ADEQUATE TO KEEP EMPLOYEE EXPOSURE TO AIRBORNE
CONCENTRATIONS BELOW RECOMMENDED EXPOSURE LIMITS.

Exposure Controls

Respiratory Protection:RESPIRATORS ARE NOT NEEDED FOR NORMAL USE.A
NIOSH/MSHA APPROVED AIR PURIFYING RESPIRATOR WITH AN ORGANIC VAPOR
CARTRIDGE OR A POSITIVE PRESSURE AIR SUPPLIED RESPIRATOR WHERE
AIRBORNE CONCENTRATIONS > TLV.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT.
Protective Gloves:LATEX OR NEOPRENE
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS OR GOGGLES
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER.IMPERVIOUS
CLOTHING SUCH AS BOOTS,APRON,WHOLE BODY SUIT MADE FROM NEOPRENE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
PART A OF TWO PARTS KIT. FOR PART B SEE SAME NSN UNDER PIN D.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.275
pH:6.5
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR,COLORLESS SOLUTION; ODORLESS
Percent Volatiles by Volume:50

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Stability Condition to Avoid:EXCESSIVE HEAT AND FLAME
Hazardous Decomposition Products:COMBUSTION MAY PRODUCE AMMONIA GAS AND
OXIDES OF NITROGEN AND SULFUR.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO FEDERAL, STATE, OR LOCAL LAWS.THIS CHEMICAL FORMULATION HAS A
LOW BIOLOGICAL OXYGEN DEMAND,AND IT IS EXPECTED TO CAUSE LITTLE
OXYGEN DEPLETION IF DI SCHARGED WITHOUT TREATMENT.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.